Rouleau de 20cm x 15 m longueur
La pièce
CONTEGA PV for well-defined, multifunctional joints between sheets of membrane or wood-based panels and surfaces that will be plastered (brick work or concrete).
The bonds meet the requirements of DIN 4108-7, SIA 180 and OENORM B 8110-2.
Material | |
Backing | PET fleece with functional membrane and plaster reinforcement |
Adhesive | special acrylate adhesive |
Release film | silicone-coated PE sheet |
Attribute | Norm | Value |
Colour | light blue / dark blue | |
Thickness | 1.3 mm | |
sd-value | EN 1931 | 2.3 m |
g-value | 11.5 MNs/g | |
Water vapor permeance | ASTM E 96 | 1.43 US perms |
Application temperature | above -10 °C / 14 °F | |
Temperature resistance | permanent -40 °C/-40 °F to +90 °C/194 °F | |
Storage | cool and dry |
Before sticking, subsurfaces should be brushed off, wiped clean with a cloth or cleaned using compressed air.
Adhesion to frozen surfaces is not possible. The substrate material must be free of water-repellent substances (e.g. grease or silicone). Remove flaking paintwork and the like. Subsurfaces must be sufficiently dry and have sufficient load-bearing capacity.
Permanent adhesion is achieved on all pro clima interior membranes and on other vapour retarder and airtight membranes (e.g. those made of PE, PA, PP and aluminium). Adhesion can be carried out on planed and painted wood, hard plastics, hard wood-based panels (chipboard, OSB and plywood panels).
The PET fleece can be embedded in the plaster layer in all substrates that can be plastered such as brick, lime sand brick, porous concrete, pumice stone, concrete etc.
For bonding joints on masonry or concrete or on rough substrates, use ORCON F.
The best results in terms of structural stability are achieved on high-quality subsurfaces.
It is your responsibility to check the suitability of the subsurface; adhesion tests are recommended in certain cases.
Pretreatment with TESCON PRIMER RP is recommended in the case of subsurfaces with insufficient load-bearing capacity.
The bonds should not be subjected to tensile strain.
Press firmly to secure the adhesive tape. Ensure there is sufficient back-pressure.
Airtight bonds can only be achieved if this adhesive tape is laid without folds or creases and are uninterrupted.
Ventilate regularly to prevent build-up of excessive humidity and use a dryer if necessary.
If the airtight connection is created straight after plastering, moisture ingress may occur in the thermal insulation or to problems in the order of construction.
CONTEGA PV alleviates this problem.